Description
01 · Find your model
The right capacity. A more comfortable pool room.
Start with how much moisture the pool produces. Then choose where the unit sits and whether you need additional room-air heating.
Lower moisture loads

CDP 40
36.2 L/day
at 30°C / 60% RH
The smallest capacity in this range, for a pool whose calculated evaporation load fits its duty.
410 m³/h airflow
46 dB(A) at 1m · in-room model
A step up in capacity

CDP 50
53.2 L/day
at 30°C / 60% RH
For pools needing more moisture removal than the CDP 40 provides, within this model’s rated duty.
680 m³/h airflow
47 dB(A) at 1m · in-room model
Highest capacity in this range

CDP 70
73.9 L/day
at 30°C / 60% RH
For higher evaporation loads that fall within the capacity of the CDP 70.
840 m³/h airflow
50 dB(A) at 1m · in-room model
Choose by evaporation load, not pool area alone. Water surface area, air and water temperatures, cover use, activity and ventilation all affect the required capacity. A small warm spa can place a high demand on a dehumidifier.
Performance shown is for the current Dantherm R454C range at the stated test conditions. It is not a guaranteed daily collection rate or a fixed pool-size limit.
INCLUDED WITH YOUR DEHUMIDIFIER
Your wireless remote. On us.
One compatible wireless controller is included at no extra charge with your Blue Cube Direct dehumidifier package. Keep control close to hand without buying the accessory remote separately.
Add only what you need.
Heating coils, floor supports and further controllers are optional extras. Installation is a separately quoted service.
02 · Choose the position
A layout that works with your pool room.
IN THE POOL ROOM

Wall mounted · CDP
The unit sits inside the pool room and takes air directly from that space. Choose CDP 40, 50 or 70 according to the capacity required.
Floor mounting is optional. Add the matching support kit if floor support better suits the room.
IN AN ADJOINING ROOM

Through the wall · CDP-T
The unit sits in a neighbouring room, with ducts and grilles carrying air through the wall. Choose the corresponding 40T, 50T or 70T unit.
Plan the duct kit. Wall openings, grilles, drainage and service access need to suit the installation.
Two versions, not two bracket positions. The through-the-wall option is a distinct CDP-T unit. Moving an in-room CDP behind a wall does not convert it into the through-wall version. Confirm the correct duct-kit inclusion with your order.
See the through-the-wall installation layout

The optional floor kit is listed for in-room CDP 40, 50 and 70, not for CDP-T units.
Watch the through-the-wall CDP-T overview
Manufacturer demonstration. Follow the manual for the supplied revision; fitting is for a suitably qualified installer.
03 · How it helps
Drier air feels better to be around.

Moisture out. Useful warmth back.
Humid room air passes through the unit, where water condenses and is led to a drain. The dried air is reheated before returning to the pool room.
Built around the pool environment.
Epoxy-coated coils and powder-coated metal parts help protect the unit. Built-in humidity and temperature controls manage operation; the supplied wireless remote brings control closer to hand.
Recovered heat is part of dehumidification. An optional heating coil provides extra air heating when the project requires it. It does not heat the pool water.
Watch the manufacturer’s CDP overview
Range overview: illustrations may show a different controller or product revision.
04 · Choose air heating
More room warmth, when you need it.
Keep the standard dehumidifier setup, or add a heating coil matched to your chosen model and the available heat source. Both heating options warm room air, not pool water.
ELECTRIC

Extra heat. No hot-water circuit.
An electrical element adds air heating inside the unit. Ask your installer to check the electrical supply and the complete installation load.
HOT WATER · LPHW

Use a suitable hot-water heat source.
A water-fed coil transfers heat from an external hot-water circuit into the room air. It needs the matching DN10 control valve, plus the required heating connections.
For CDP 40 / 40T
2kW electric air heating
or
LPHW coil for model 40
With LPHW: add the DN10 control valve.
For CDP 50 / 50T
3.5kW electric air heating
or
LPHW coil for model 50
With LPHW: add the DN10 control valve.
For CDP 70 / 70T
5kW electric air heating
or
LPHW coil for model 70
With LPHW: add the DN10 control valve.
Choose the matching model. A coil for one capacity is not a universal coil for the range. Electric and LPHW are alternative heating choices; do not add both without an approved design. LPHW output depends on water temperatures and operating conditions.
Heating options, the LPHW valve and fitting cost extra. The external hot-water heat source and pipework are separate.
Installer video: electric air-heating coil
Manufacturer demonstration. Follow the manual for the supplied revision; fitting is for a suitably qualified installer.
Installer video: LPHW air-heating coil
Manufacturer demonstration. Follow the manual for the supplied revision; fitting is for a suitably qualified installer.
05 · Complete the setup
Useful extras. Clear compatibility.

Floor mounting kit
CDP 40 / 50 / 70 · IN-ROOM ONLY
Supports the dehumidifier from the floor when wall mounting does not suit your layout. Optional; not listed for the CDP-T versions.

DN10 control valve
CDP / CDP-T 40 / 50 / 70 · LPHW ONLY
Controls hot-water flow to the LPHW heating coil. Add it with the water-heating option; it is not required for an electric coil.
Spare wireless controller
MATCH TO THE UNIT’S CONTROLLER VERSION
For a spare or replacement. There is no need to buy a separate accessory remote to operate your new package. Check the controller revision before ordering another.
Other project-specific accessories
Dantherm also lists a Pro 30 exhaust fan and an external humidity/temperature sensor for the CDP and CDP-T 40 / 50 / 70 families. Through-wall projects need suitable ducts and grilles; some arrangements may need a duct lead-in adapter. These are project-specific additions, not assumed inclusions.
06 · Installation support
Less uncertainty about fitting.
Get the fitting planned with the equipment.
Installation is available as a chargeable extra through our partners at Blue Cube Pools. Their award-winning team is SPATA- and BISHTA-trained and can discuss the requirements of your project.
Request a quote covering the unit’s position, mounting, condensate drain, electrical work and any heating connections. Scope, availability and cost depend on your location and installation.
Installation is not included in the equipment price. Blue Cube Pools holds SPATA awards; this describes the team’s credentials, not an award for this individual product.
07 · Compare the detail
The numbers behind your choice.
All three model families operate at 10–36°C and 40–95% RH, with a 230V single-phase / 50Hz supply and protective earth. Each has a PPI 15 filter and an IPX4 rating.
| Specification | CDP 40 | CDP 50 | CDP 70 |
|---|---|---|---|
| Moisture removal · 30°C / 60% RH (L/day) | 36.2 | 53.2 | 73.9 |
| Moisture removal · 20°C / 60% RH (L/day) | 20.1 | 29.7 | 43.2 |
| Airflow (m³/h) | 410 | 680 | 840 |
| In-room dimensions · W × D × H (mm) | 1010 × 326 × 770 | 1160 × 326 × 770 | 1495 × 326 × 770 |
| In-room weight (kg) | 55.2 | 63.5 | 77 |
| In-room sound pressure at 1m (dB(A)) | 46 | 47 | 50 |
Full technical comparison · including CDP-T
| Specification | 40 / 40T | 50 / 50T | 70 / 70T |
|---|---|---|---|
| Moisture removal · 30°C / 60% RH (L/day) | 36.2 | 53.2 | 73.9 |
| Moisture removal · 20°C / 60% RH (L/day) | 20.1 | 29.7 | 43.2 |
| Airflow (m³/h) | 410 | 680 | 840 |
| Energy per litre · 30°C / 60% RH (kWh/L) | 0.44 | 0.47 | 0.45 |
| Energy per litre · 20°C / 60% RH (kWh/L) | 0.60 | 0.61 | 0.59 |
| Maximum current · base unit (A) | 3.8 | 5.8 | 7.7 |
| Maximum power · base unit (kW) | 0.9 | 1.4 | 1.7 |
| Power input · 30°C / 60% RH (kW) | 0.7 | 1.0 | 1.4 |
| Power input · 20°C / 60% RH (kW) | 0.5 | 0.8 | 1.1 |
| Maximum power with electric heater (kW) | 3.1 | 4.9 | 6.7 |
| Heat recovered · 30°C / 60% RH (kW) | 1.9 | 2.7 | 3.5 |
| Heat recovered · 20°C / 60% RH (kW) | 1.2 | 1.6 | 2.3 |
| R454C charge / CO₂ equivalent (kg / t) | 0.7 / 0.11 | 0.8 / 0.12 | 1.2 / 0.18 |
| In-room dimensions · W × D × H (mm) | 1010 × 326 × 770 | 1160 × 326 × 770 | 1495 × 326 × 770 |
| In-room weight (kg) | 55.2 | 63.5 | 77 |
| In-room sound pressure at 1m (dB(A)) | 46 | 47 | 50 |
| Through-wall dimensions · W × D × H (mm) | 998 × 304 × 700 | 1148 × 304 × 700 | 1483 × 304 × 700 |
| Through-wall weight (kg) | 55.6 | 64 | 77.9 |
| Through-wall sound pressure at 1m (dB(A)) | 43 | 44 | 47 |
Controls and construction
Electronic hygrostat and thermostat; integrated on/off humidity and heating control; Modbus RS485 BMS communication; demand-controlled defrost. Coils are epoxy coated and metal parts powder coated before assembly.
Ratings are taken from the current Dantherm R454C product information. Extraction changes with conditions. Optional heater output, recovered heat and electrical input are different measurements. Use the manual and data for your actual supplied unit, especially when replacing older Vaporex equipment.
08 · Useful documents
The right details, close to hand.
Current Dantherm information
Model details and access to the current manuals on Dantherm’s website.
Pool hall construction guide
2022 guidance covering the building and pool-hall environment around the equipment.
Older Vaporex reference documents
These legacy documents remain useful for identifying earlier equipment. Their refrigerant, controller and performance information may differ from the current Dantherm range.
09 · Before you order
A few useful answers.
Which model suits my indoor pool?
Use the calculated evaporation load. Water surface area, water and air temperatures, cover use, ventilation and activity matter. Pool-room floor area or pool volume alone cannot establish the correct unit.
Is the remote control free?
Yes. One compatible wireless remote is included at no extra charge in your Blue Cube Direct dehumidifier package. Further or replacement controllers are separate accessories.
Do I need additional air heating?
That depends on the room’s heat requirement. The dehumidifier returns recovered heat to the air; optional electric or LPHW coils provide additional room-air heating when needed.
Can the wall-mounted model go in a plant room?
Choose the corresponding CDP-T through-the-wall version for an adjoining-room installation, together with suitable ducts and grilles. The standard in-room unit is not the same product.
Can it replace my older Vaporex unit?
Have the existing rating plate, dimensions, mounting, drainage and electrical supply checked. Similar product names do not establish a direct replacement.